WSA/WSI
Industrial Chiller 955-6.348 kBTU/hr
Air-cooled industrial liquid chiller
Cooling Capacity
955 – 6.348 kBTU/hr
Compressors
a Vite
Protection
Refrigerant
R513A (WSA) / R1234ze (WSI)
WSA is a range of air-cooled liquid chillers offering high efficiency and low environmental impact, featuring free-cooling technology and cooling capacities ranging from 955 to 6.348 kBTU/hr.
Designed for process cooling applications operating 24/7, 365 days a year, the new WSA–WSI liquid chillers feature one or two refrigeration circuits with stepless screw compressors (WSA) or inverter-driven compressors (WSI), and utilize either plate heat exchangers or dry-expansion shell-and-tube evaporators with a large heat exchange surface. The WSA/WSI range is characterized by high levels of energy efficiency (Class A or B), enabling compliance with the requirements of the 2009/125/EC Ecodesign ErP 2021 Directive.
Thanks to the special W-shaped configuration of the microchannel heat exchanger coils and their optimized sizing, these units achieve some of the highest specific power levels (kW per footprint area) available in their category.

HT version for applications with high-temperature water (e.g.: plastic)
The refrigeration circuit of the HT version is specifically designed to produce chilled water with evaporator outlet temperatures from 59°F to 77°F. The compressor has an oversized motor, allowing for wide operating limits and high suction temperatures.
Low Noise Version
Even in the Low Noise version, which is ideal for installations near residential areas, our units maintain high performance and high energy savings, guaranteeing low noise levels. The compressor casing effectively reduces transmitted noise (-4dBA), thanks to a specific acoustic insulating composite lining.
LT Chiller version for ambient temperatures down to -4°F
Thanks to a sophisticated condensation control system based on the partialisation of the condensation surface and the control of EC fan speeds, the CHILLER LT version is capable of operating with ambient temperatures down to -4°F.
Free Cooling
WSA ErP chillers are available with an Integrated Free Cooling version, delivering significant energy savings, particularly in applications requiring high cooling fluid temperatures (such as plastics processing) and installations located in cold or temperate climates.
By using outdoor air to cool the process fluid, the Free Cooling system can completely replace the refrigeration circuit under suitable operating conditions, allowing the compressors to be switched off entirely.
The heat exchangers have been specifically sized to achieve a Total Free Cooling Temperature (TFT) that is 10°C lower than the set-point temperature. WSA–WSI units can also be combined with FCB free cooling modules, which maximize free-cooling performance by further increasing the Total Free Cooling Temperature (TFT).
Broad operating limits
Every application has different requirements based on ambient temperature, fluid temperature, positioning, noise level, etc. Cosmotec is able to meet the most diverse needs, thanks to a wide range of options and the possibility of extending the operating limits of the WSA series chillers, if required.
Very hot and dusty environment
WSA chillers are fitted with metal air filters to protect the condensers from dust and dirt. Operation is possible up to 131°F with the Unloading function. 100% cooling capacity is guaranteed up to 113°F. If the temperature rises, the Unloading function reduces the load on the compressors without switching them off.
Very cold environment
The compressor compartment is closed and heating elements are installed to protect the electrical panel, compressors, evaporator and the entire hydraulic circuit. The Free Cooling reaches down to -40°F (in a special version) with components specifically selected to guarantee a long life for the entire chiller.
High-temperature water applications (plastic)
The cooling circuit is specially designed to achieve high delivery temperatures. The compressor has wide operating limits and a high suction temperature.
Low GWP (Global Warming Potential) version
The WSA – WSI units are available in two environmentally friendly versions that ensure a reduction in global warming potential: HFO R1234ze refrigerant fluid (GWP = 7) classified as A2L non-toxic, slightly flammable, and with zero impact on the ozone layer (WSA-WSI). R513A refrigerant fluid (GWP = 572) classified as A1 non-toxic, non-flammable, and with zero impact on the ozone layer (WSA).
Perfect applications for this product
Other coolers you might be interested in
- AIR-COOLED R1234yf

WLA Compact
APPLICAZIONE INDUSTRIALE 3,4–17,1 kBTU/hr Find out more: WLA Compact - AIR-COOLED R513A

WRA
APPLICAZIONE INDUSTRIALE 16 – 75 kW Find out more: WRA - AIR-COOLED R32

WLA Precision
APPLICAZIONE INDUSTRIALE 205 - 546 kBTU/hr Find out more: WLA Precision - AIR-COOLED R32

WPA Mini
SCROLL COMPRESSORS 324 – 580 kBTU/hr Find out more: WPA Mini - AIR-COOLED R454B

WPA
SCROLL COMPRESSORS 563 – 1.911 kBTU/hr Find out more: WPA - AIR-COOLED R513A R1234ze

WSA/WSI
SCREW COMPRESSORS 955 – 6.348 kBTU/hr Find out more: WSA/WSI - WATER-COOLED R513A

WSW
SCREW COMPRESSORS 805 – 5.216 kBTU/hr Find out more: WSW - FOR OIL COOLING –

ORA
APPLICAZIONE INDUSTRIALE – Find out more: ORA

Speak with one of our experts and find the ideal cooling solution for your system.
Our specialists are available to provide you with a detailed analysis and dedicated technical consulting.