F-GAS 2027

The transition to refrigerants with a low environmental impact is transforming the industrial cooling and air conditioning sector. With the entry into force of the new EU F-Gas Regulation 2024/573, the European Union has established a pathway for the gradual reduction of fluorinated gases with a high GWP (Global Warming Potential), introducing new requirements for manufacturers, equipment builders and users of refrigeration and air conditioning equipment.

Here you can discover how cosmotec is preparing for this evolution by developing new solutions with low-GWP refrigerants and updating its product range to ensure compliance with the most advanced environmental standards, without compromising safety, reliability or operational continuity in critical applications.

EU F-Gas Regulation 2024/573

Regulation (EU) 2024/573 aims to progressively reduce emissions of fluorinated greenhouse gases (F-Gases) into the atmosphere, as these have a significant impact on climate change, while promoting the adoption of alternative substances. Among the F-Gases regulated by the Regulation are the fluorinated refrigerants used in refrigeration, air conditioning and heat pump systems.

The F-Gas Regulation introduces restrictions on the placing on the market and export of refrigerants or products containing them. Placing on the market means the first making available of goods within the EU through sale or transfer by an EU manufacturer or through importation. Export means their movement out of the EU customs territory. It is important to note that the restrictions do not apply to subsequent sales or transfers after the first placing on the EU market.

The first restrictions affecting cosmotec products for industrial cooling will come into force from 1 January 2027.

PLACING ON THE EU MARKET

  • Chillers and monobloc air conditioners with a rated capacity up to 12 kW: permitted GWP below 150.
  • Chillers with a rated capacity above 12 kW: permitted GWP below 750.

EXPORT

For monobloc air conditioners and chillers of any cooling capacity, the maximum permitted GWP is 1000.

The supply of products (for further distribution, incorporation into a final product, further processing or refinement) for the purpose of exporting the final product outside the EU market is not considered placing on the market. The applicable limit is therefore the one established for exports: GWP < 1000.

Pursuant to Article 11(5), the European Commission may authorize temporary derogations for specific product categories where no alternative solutions are available, where such alternatives are not feasible for technical or safety reasons, or where their use would entail disproportionate costs. At present, no derogation request has been approved for industrial cooling products.

Annex IV of the Regulation provides an exemption for specific safety reasons related to the site where the cooling equipment operates or to the equipment into which it is integrated, such as an electrical enclosure or a machine tool. Air conditioners and chillers covered by an exemption may use refrigerants with a GWP below 750. Unlike a general derogation, this specific exemption does not require approval by the European Commission. The burden of proof lies with the operator (end user), who must be provided with a risk assessment demonstrating the safety reasons justifying the exemption.

Overview of technically viable alternative refrigerants

The traditional refrigerants used in industrial cooling products, R134a, R407C and R410A, exceed the limits set by the Regulation. Below is an overview of technically viable alternative refrigerants.

Natural refrigerants

Minimal environmental impact, but high application complexity

It offers excellent energy performance and an almost negligible environmental impact. However, its high flammability limits its possible applications.

Traditional natural refrigerant historically used in industrial refrigeration. Operating pressures are very high and it offers limited efficiency in industrial air conditioning applications.

Despite their very low GWP, natural refrigerants present some application challenges: R290 is highly flammable and has significant limitations for safe use, while R744 results in high energy consumption when applied to industrial air conditioning, offsetting the environmental benefits of its low GWP. The choice of refrigerant must consider not only GWP, but also safety, performance and overall long-term sustainability.

Low-GWP fluorinated refrigerants

Maximum sustainability, but with flammability to manage

Guarantees performance comparable to that of traditional refrigerants while delivering an extremely low global warming potential.

Good energy efficiency solution, but requires larger-sized equipment.

Refrigerant that meets the Regulation’s GWP requirements while maintaining high operational performance.

Although characterized by a low GWP, these refrigerants are classified as mildly flammable and therefore require specific safety assessments based on the equipment to be cooled and the installation environment.

Intermediate-GWP fluorinated refrigerants

R513A: the non-flammable alternative for safety-critical applications

It represents one of the leading solutions for applications requiring high safety standards. Its main advantage is its non-flammability, combined with proven performance and broad compatibility with industrial applications.

Refrigerant used in numerous next-generation HVAC applications.

Refrigerant widely used in the air conditioning sector thanks to its good balance between energy efficiency and reduced GWP.

These refrigerants have a GWP between 150 and 750. The F-Gas Regulation allows their use in equipment below 12 kW operating in the EU only under exemption provisions, when safety requirements or technical constraints make the use of lower-GWP alternatives impractical. In this context, R513A stands out as the only non-flammable refrigerant in this category, offering a significant advantage for the most critical industrial applications.

cosmotec strategy between safety and sustainability

The approach we adopt is based on a simple principle:

to provide you with the most sustainable and safest refrigerant for your application

Technical analyses show that, for many installations on electrical enclosures and industrial machinery, the use of flammable refrigerants may introduce unacceptable risks. For these applications, cosmotec offers solutions using R513A, a non-flammable refrigerant (A1 classification) with a GWP of 631, which can be used under the exemptions provided for by the Regulation.

Download the executive summary on the use of refrigerants in industrial air conditioners for electrical enclosures and in chillers:

Air conditioners and chillers with a cooling capacity below 12 kW using R513A refrigerant will be provided with the label shown here. This label indicates that their use in the EU is permitted only when safety considerations prevent the use of flammable refrigerants. The operator (end user) of the cooling device or of the system into which the device is integrated must be provided with a risk assessment demonstrating the safety reasons that justify the exemption.

Where the risk assessment allows the use of mildly flammable refrigerants, cosmotec expands its offering with new product ranges based on R1234yf, a more environmentally friendly refrigerant, characterized by a GWP of 0.5.

New air conditioners with R513A and R1234yf

The entire cosmotec range of air conditioners has already been converted to the R513A refrigerant, a non-flammable solution that ensures safety, reliability and application continuity in the most demanding industrial installations. From January 2027, Protherm, SlimIn and Top units in the CE version using R1234yf refrigerant, characterized by a GWP of 0.5, well below regulatory limits, will be available for delivery. This evolution maintains the same performance, dimensions and mounting cut-out of the current R513A range, offering customers more environmentally friendly solutions with the same advantages in terms of ease of installation and integration into their equipment, ensuring full application continuity.

Capacity< 12 kW
GWP LimitEU under exemption: 750 / Export: 1000
GWP631
Availability✔
CertificationsUL LISTED / CE
Capacity< 12 kW
GWP LimitEU without exemption: 150
GWP0,5
Availabilityfrom January 2027
CertificationsCE

New chillers with R32, R513A and R1234yf

For WLA Compact and WRA chillers below 12 kW, even when installed on machinery, safety analyses have identified only limited critical issues related to the use of mildly flammable refrigerants. For this reason, we have developed the new range using R1234yf refrigerant. For the most critical applications operating under exemption provisions, versions with R513A refrigerant are available on request.

With this development, the entire chiller range covering cooling capacities from 1 to 12 kW is available with R1234yf, in compliance with the requirements of the F-Gas Regulation.

The WRA range above 12 kW has been fully converted to the R513A refrigerant.

WLA Precision chillers, on the other hand, are available with R32 refrigerant, the most widely used refrigerant for units in this cooling capacity range. Since these chillers are installed as standalone units rather than integrated into machinery, the use of an A2L refrigerant such as R32 is only rarely a critical safety concern.

PRODUCTCAPACITYGWP LIMIT IN THE EUREFRIGERANTGWPGO TO THE PRODUCT PAGE
WLA Compact< 12 kW150R1234yf0,5 Web Page
WRA ErP 13‑20‑25‑30‑35< 12 kW150R1234yf0,5 PDF Datasheet
WRA ErP 50‑55‑65‑80‑90-0A‑5A‑8A‑0B> 12 kW750R513A631 Web Page
WLA Precision> 12 kW750R32675 Web Page

WLA Compact and WRA units below 12 kW with R513A refrigerant are available on request.

Download the complete guide to the transition to the new WRA and WLA Compact units

Discover all the updates related to the adoption of R513A and R1234yf refrigerants. Inside the document, you will find the correspondence between current models and next-generation units, the main technical and dimensional differences, as well as ordering and delivery schedules.

Would you like to stay up to date on F-Gas regulations and the latest industry developments?

Receive insights, regulatory updates, events, and exclusive content from cosmotec directly in your inbox.

Fill out the form below, and one of our experts will get back to you very shortly!